Methods for reducing the temperature components of magnetomodulation DC convertors errors

Sulton AmirovNavoi State University of Mining and Technologies, Navoi, UzbekistanNodir O. AtaullayevNavoi State University of Mining and Technologies, Navoi, UzbekistanAmin O. AtaullayevNavoi State University of Mining and Technologies, Navoi, UzbekistanBobur Q. MuxammadovNavoi State University of Mining and Technologies, Navoi, UzbekistanAhror U. MajidovNavoi State University of Mining and Technologies, Navoi, Uzbekistan
E3S Web of Conferencesjournal2023en
ABI

Annotatsiya

Reliability is called not only one of the main characteristics of the magnetic modulation DC converters, but also the ability to correctly perform the required function of the measuring device in the specified operating modes and operating conditions for a certain period of time. One of the main tasks in the development of magnetic modulation DC converters is to reduce the number of inference errors. Magnetic modulation DC converters errors include the main errors which are technological and corrective errors, internal sources of additional errors, external sources of additional errors which can be static errors, dynamic errors.