Asosiy kontentga oʻtish
AkademIndex

Mahsulotlar

Ishlab chiquvchilar uchun

AkademBasetez oradaEkotizim uchun ochiq API
Lotin
Maqola

Calculations of epithermal neutron absorbed dose in the phantom object

Gayratulla A. KulabdullaevInstitute of Nuclear Physics, Academy of Sciences of Uzbekistan, 1 Khuroson, Ulugbek, 100214, Tashkent, UzbekistanAndrey A. KimInstitute of Nuclear Physics, Academy of Sciences of Uzbekistan, 1 Khuroson, Ulugbek, 100214, Tashkent, UzbekistanGayana A. AbdullaevaInstitute of Nuclear Physics, Academy of Sciences of Uzbekistan, 1 Khuroson, Ulugbek, 100214, Tashkent, UzbekistanDjasur O. YuldashevInstitute of Nuclear Physics, Academy of Sciences of Uzbekistan, 1 Khuroson, Ulugbek, 100214, Tashkent, UzbekistanG. T. DjuraevaInstitute of Nuclear Physics, Academy of Sciences of Uzbekistan, 1 Khuroson, Ulugbek, 100214, Tashkent, Uzbekistan
ABI

Annotatsiya

To determine the absorbed dose in biological samples when irradiated with an epithermal neutron beam of the VVR-SM reactor (INP AS RUz), calculations were made for a phantom object. The flux modification and Kerma reducing values were determined for the incoming neutron beam that goes into the phantom.