Asosiy kontentga oʻtish
AkademIndex

Mahsulotlar

Ishlab chiquvchilar uchun

AkademBaseEkotizim uchun ochiq API
Maqola

Closed-Loop Diabetes Minipatch Based on a Biosensor and an Electroosmotic Pump on Hollow Biodegradable Microneedles

Xiaojin LuoSchool of Materials Science and Engineering, Peking University, Beijing 100871, P. R. ChinaQi YuRenal Division, Peking University First Hospital; Peking University Institute of Nephrology; Key Laboratory of Renal Disease, Ministry of Health of China; Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing 100034, P. R. ChinaYiqun LiuSchool of Materials Science and Engineering, Peking University, Beijing 100871, P. R. ChinaWeixin GaiSchool of Integrated Circuits, Peking University, Beijing 100871, P. R. ChinaLe YeSchool of Integrated Circuits, Peking University, Beijing 100871, P. R. ChinaLi YangRenal Division, Peking University First Hospital; Peking University Institute of Nephrology; Key Laboratory of Renal Disease, Ministry of Health of China; Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing 100034, P. R. ChinaYue CuiSchool of Materials Science and Engineering, Peking University, Beijing 100871, P. R. China
2022en
ABI

Annotatsiya

Developing a miniaturized, low-cost, and smart closed-loop system for diabetes could significantly improve life quality and benefit millions of people. Conventional closed-loop devices are large in size and exorbitant. Here, we unprecedentedly demonstrate an electrically controlled flexible closed-loop patch for continuous diabetes management by integrating hollow biodegradable microneedles with a biosensing device and an electroosmotic pump. The hollow microneedles were fabricated using a combination of soft lithography and micromachining. The outer layer of the microneedles was functionalized to serve as a biosensing device for the in situ sensitive and accurate monitoring of interstitial glucose. The inner layer of the microneedles was integrated with a flexible electroosmotic pump to deliver insulin, and the delivery rate was electrically controlled by the glucose level from the biosensing device. The closed-loop system successfully stabilized the blood glucose levels of diabetic rats in a normal and safe range. The system is painless, miniaturized, cost-effective, and flexible. It is anticipated that it could open up exciting new avenues for fundamental studies of new closed-loop devices as well as practical applications for diabetes management.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar

2 ta iqtibos0 ta foydalanilgan manba