Direct detection of explosives on solid surfaces by mass spectrometry with an ambient ion source based on dielectric barrier discharge

Na NaDepartment of Chemistry, Key Laboratory for Atomic and Molecular Nanosciences of the Education Ministry, Tsinghua University, 100084 Beijing, P. R. ChinaChao ZhangNational Institute of Metrology P. R. China, 100013, Beijing, P. R. ChinaMengxia ZhaoDepartment of Chemistry, Key Laboratory for Atomic and Molecular Nanosciences of the Education Ministry, Tsinghua University, 100084, Beijing, P. R. ChinaSichun ZhangDepartment of Chemistry, Key Laboratory for Atomic and Molecular Nanosciences of the Education Ministry, Tsinghua University, 100084, Beijing, P. R. ChinaChengdui YangDepartment of Chemistry, Key Laboratory for Atomic and Molecular Nanosciences of the Education Ministry, Tsinghua University, 100084, Beijing, P. R. ChinaXiang FangNational Institute of Metrology P. R. China, 100013, Beijing, P. R. ChinaXinrong ZhangDepartment of Chemistry, Key Laboratory for Atomic and Molecular Nanosciences of the Education Ministry, Tsinghua University, 100084, Beijing, P. R. China
2007en
ABI

Annotatsiya

Trace amounts of explosives on solid surfaces were detected by mass spectrometry at ambient conditions with a new technique termed dielectric barrier discharge ionization (DBDI). By the needle-plate discharge mode, a plasma discharge with energetic electrons was generated, which could launch the desorption and ionization of the explosives from solid surfaces. Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), 2,4,6-trinitrotoluene (TNT), and pentaerythritol tetranitrate (PETN) were desorbed directly from the explosives-contaminated surface by DBDI, forming the typical anions of [TNT](-), [TNT - H](-), [RDX + NO(2)](-), [PETN + ONO(2)](-), and [RDX + ONO(2)](-). The ions were transferred into the MS instrument for analysis in the negative ion mode. The detection limit of present method was 10 pg for TNT (m/z 197, S/N 8 : 1), 0.1 ng for RDX (m/z 284, S/N 10 : 1), and 1 ng for PETN (m/z 260, S/N 12 : 1). The present method allowed the detection of trace explosives on various matrices, including paper, cloth, chemical fiber, glass, paints, and soil. A relative standard deviation of 5.57% was achieved by depositing 100 pg of TNT on these matrices. The analysis of A-5, a mixture of RDX and additives, has been carried out and the results were consistent with the reference values. The DBDI-MS method represents a simple and rapid way for the detection of explosives with high sensitivity and specificity, which is especially useful when they are present in trace amounts on ordinary environmental surfaces.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar

4 ta iqtibos0 ta foydalanilgan manba