Asosiy kontentga oʻtish
AkademIndex

Mahsulotlar

Ishlab chiquvchilar uchun

AkademBaseEkotizim uchun ochiq API
Maqola

The analysis of the performance of a sewage pump in terms of the wear of hydraulic components

O MoloshnyiApplied Hydro–and Aeromechanics department, Sumy State University, Sumy 40007, UkrainePaulina SzulcDepartment of Mechanics, Machines, Devices and Energy Processes, Wroclaw University of Science and Technology, Wroclaw, 50–370, PolandGrzegorz MolińskiSerhii Viacheslavovych SapozhnikovApplied Hydro–and Aeromechanics department, Sumy State University, Sumy 40007, UkraineSerhii Serhiiovych AntonenkoApplied Hydro–and Aeromechanics department, Sumy State University, Sumy 40007, Ukraine
2021en
ABI

Annotatsiya

Abstract The paper presents the comparison of the performance of the three-blade centrifugal pump operating in sewage water in the function of time. Two conditions of the analysed pump were investigated: a new one and one after a long period of utilization. The main objects of research were the impeller, due to its enormous wear, and the L–shape wear ring. Three dimensional optical scanning was applied to reflect the real geometrical parameters of the analysed pump. The investigations were conducted by means of numerical simulations and a real test. The achieved results indicate the impact of the wear on the performance curves of middle specific speed sewage pump.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar

2 ta iqtibos0 ta foydalanilgan manba