Noise as an indicator of cavitation in a centrifugal pump

M. ChudinaFaculty of Mechanical Engineering, University of Ljubljana, Askerceva 6, 1000, Ljubljana, Slovenia
2003en
ABI

Annotatsiya

One of the sources of instability in a centrifugal pump is cavitation within the pump. Cavitation of a centrifugal pump is the result of insufficient net positive suction head (NPSH) and can occur within the entire range of operating conditions. Cavitation may cause three different and undesirable effects: (1) a drop in head-capacity and efficiency curves, (2) damage to the impeller by pitting and erosion, and (3) structure vibration and resulting noise. Therefore, the cavitation process must be prevented by all means. To prevent the onset of cavitation we have to detect the beginning of the cavitation process in the pump. To detect the beginning of the cavitation process, the emitted noise can be used, among other possibilities. Specifically, a noise spectra structure can be used to detect the beginning of cavitation and its development. Experiments have shown that there is a discrete frequency tone, at 147 Hz, which is strongly dependent on the cavitation process and its development. Therefore, noise spectra can also be used to determine the NPSH required or the critical value, representing the upper limit of the permissible pump operation without cavitation.

Hali tarjima qilinmagan

Identifikatorlar

Iqtiboslar va manbalar

2 ta iqtibos0 ta foydalanilgan manba