[?쇰Ц] ?곗냼二쇱엯 ?섏쿂由?諛쒖쟾?뚯슜 湲됱닔?뚰봽 諛遊됱옣移섏쓽 ?꾩꽕諛⑹?

2011uz
ABI

Аннотация

ABSTRACT: The identifying cause of leakage problems on mechanical seal in a feed water pump of power plant have been difficult because of technical limits of domestic mechanical seal manufacturer and the various conditions of power plants. This paper can get a conclusion through the consideration study and experiment test of mechanical seal characteristics of feed water pump depending on oxygen treatment as follows. The oxygen treatment increase dissolved oxygen and cause a corrosion on the mechanical seal stationary ring composed of antimony as well as leakage problems. For solving leakage problems of seal, to eliminate dissolved oxygen in the cooling water of seal with hydrazine injection can prevent leakage problems of mechanical seal in feed water pump.