Experimental Study of Distance between Evaporator and Condensate of Inclined Multistage Desalination Plant

Mirfayz MirzaevBukhara State University, 705018, Bukhara, UzbekistanK. A. SamievBukhara State University, 705018, Bukhara, UzbekistanSh. M. MirzaevBukhara State University, 705018, Bukhara, Uzbekistan
Applied Solar Energyjournal2019en
ABI

Аннотация

An experimentally designed and researched inclined multistage laboratory pilot desalination plant is installed so as to run with the highest productivity at a distance of four to eight centimeters between the evaporator and the condensate, especially at 5.21 cm. The evaporator’s unit sizes are chosen according to the calculation procedure proposed by the authors of this article.