Forebays of the poligonal cross-section of the irrigating pumping station

Bakhtiyar MatyakubovTashkent Institute of Irrigation and Agricultural Mechanization Engineers, Tashkent, UzbekistanM MamajonovAndijan branch of Tashkent State Agrarian University, Andijan, UzbekistanB ShakirovAndijan branch of Tashkent State Agrarian University, Andijan, UzbekistanG TeplovaTashkent Institute of Irrigation and Agricultural Mechanization Engineers, Tashkent, Uzbekistan
ABI

Аннотация

Abstract The article discusses the use of the design of the forebays of a polygonal cross-section to improve the hydraulic characteristics of the water intake structures of pumping stations, in which the longitudinal slope in the direction of the middle chamber is i = 0.1 , the adjacent longitudinal slope is 0.15 and with the extreme chambers the longitudinal the slope is 0.2. The faces of each chamber with a forebay have a transverse slope equal to i c = 0.1 and the angle of taper of the forebays in the plan is α = 35°. In the joint operation of 5 pumps, for the forebays of a polygonal cross-section, the total resistance coefficient is ∑ξ total ext. = 0.568 and for a typical ∑ξ total ext. = 0.72 . With the simultaneous operation of 5 pumps, the average supply of 3 pumps is 0.0051 m 3 /s, 2, and 4 pumps, respectively 0.00498 … 0.00504 m 3 /s , for 1 and 5 pumps, 0.00478, and 0.00481 m 3 /s , respectively at the extreme pumps, the flow rate increases by 4.9…6.3% relative to the standard forebays.