Asosiy kontentga oʻtish
AkademIndex

Mahsulotlar

Ishlab chiquvchilar uchun

AkademBasetez oradaEkotizim uchun ochiq API
Lotin
Oʻzbek
Maqola

Enhanced External Counterpulsation Intervention Induces the Variation of Physiological Parameters and Shear Stress Metrics in the Carotid Artery

Zhenfeng RenKey Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Key Laboratory of Innovation and Transformation of Advanced Medical Devices, Ministry of Industry and Information Technology, National Medical Innovation Platform for Industry-Education Integration in Advanced Medical Devices (Interdiscipline of Medicine and Engineering), School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, ChinaZi’an WuMedical Research Center, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen 518033, ChinaYanjing WangKey Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Key Laboratory of Innovation and Transformation of Advanced Medical Devices, Ministry of Industry and Information Technology, National Medical Innovation Platform for Industry-Education Integration in Advanced Medical Devices (Interdiscipline of Medicine and Engineering), School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, ChinaIsrailov JakhongirkhonDepartment of Public Health and Administration, Tashkent Medical Academy, Tashkent 100109, UzbekistanQianxiang ZhouKey Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Key Laboratory of Innovation and Transformation of Advanced Medical Devices, Ministry of Industry and Information Technology, National Medical Innovation Platform for Industry-Education Integration in Advanced Medical Devices (Interdiscipline of Medicine and Engineering), School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, ChinaJianhang DuMedical Research Center, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen 518033, China
Bioengineeringjournal2025en
ABI

Annotatsiya

Enhanced external counterpulsation (EECP) treatment has been demonstrated to be effectively vasculoprotective and anti-atherosclerotic in clinical observations and controlled trials. The diastolic blood flow augmentation induced by EECP greatly affected the local hemodynamic environment in multiple arterial segments. In this study, a porcine model of hypercholesterolaemia was developed to perform an invasive physiological measurement involving electrocardiogram, blood flow wave, and arterial pressure. Subsequently, a three-dimensional carotid bifurcation model was developed to evaluate the variations in wall shear stress (WSS) and its temporal and spatial oscillations. The results show that, compared to the pre-EECP state, EECP stimulus led to an increase of 28.7% in the common carotid artery (CCA) blood flow volume over a cardiac cycle, as well as an augmentation of 22.73% in the diastolic pressure. Meanwhile, the time-average wall shear stress (TAWSS) over the cardiac cycle increased 25.1%, while the relative residence time (RRT) declined 45.7%. These results may serve to reveal the hemodynamic mechanism of EECP treatment that contributes to its anti-atherosclerotic effects.

Mavzular

Identifikatorlar

Iqtiboslar va manbalar

Koʻrsatkichlar — AkademScholar · Tez orada