Concentrating performances of an ellipsoid-cone system for optical furnaces
Sh. R. NurmatovScientific Production Association “Akadempribor,”, Academy of Sciences of Uzbekistan, Tashkent, UzbekistanA. A. AbdurakhmanovScientific Production Association “Akadempribor,”, Academy of Sciences of Uzbekistan, Tashkent, UzbekistanSh. A. FaisievScientific Production Association “Akadempribor,”, Academy of Sciences of Uzbekistan, Tashkent, UzbekistanZ. Sh. KlychevScientific Production Association “Akadempribor,”, Academy of Sciences of Uzbekistan, Tashkent, UzbekistanSh. I. KlychevScientific Production Association “Akadempribor,”, Academy of Sciences of Uzbekistan, Tashkent, Uzbekistan
ABI
Annotatsiya
A way to increase the concentration in an URAN optical furnace by means of a secondary concentrator (C) is examined. The opening angle of the concentrator is optimized. It is revealed that by using the concentrator, it is possible to increase the mean irradiance to a spot of 10 mm in diameter by almost a factor of 2.
Mavzular
Identifikatorlar
Iqtiboslar va manbalar
1 ta iqtibos0 ta foydalanilgan manba
Koʻrsatkichlar — AkademScholar · Tez orada